Known Issues

Title Category Resolutionsort descending Description Posted Updated
ondemand gpu request error Nov 2021 Batch, OnDemand, Pitzer Resolved

When requesting an interactive session in ondemand and requesting gpu resources, users may see an error similar similar to  "sbatch: error: Invalid generic resource (gres) specification"

...

Read more
4 years 10 months ago 4 years 10 months ago
HPC Job Activity Table: Save Report client portal Resolved

If you save a report at the HPC Job Activity Table, you must exit out of your web browser in order to have the report saved correctly and be able to switch in between the reports.

There is...

Read more
7 years 2 months ago 6 years 7 months ago
MPI fails with UCX 1.18 Software Resolved
(workaround)

After the downtime on August 19, 2025, users may encounter UCX errors such as:

UCX ERROR no active messages transport to <no debug data>: self/memory -...
Read more
1 year 1 month ago 1 year 3 days ago
my.osc.edu is NOT available Account Management Resolved

my.osc.edu has not been fully restored after yesterday's downtime. You can change your password, but you will not be able to use the new password on my.osc.edu. The updated password will work to...

Read more
9 years 4 months ago 9 years 4 months ago
MOE license server down Licensing Resolved

The MOE license server is experiencing an unknown issue and potentially down.  We are working to resolve the issue.

3 years 3 weeks ago 3 years 3 weeks ago
vLLM versions prior to 0.14.1 are deprecated Software Resolved

vLLM versions prior to 0.14.1 are deprecated due to security issue CVE-2026-22778 which can allow remote code execution.  Clients are advised to use versions 0....

Read more
7 months 4 weeks ago 7 months 4 weeks ago
Lustre, Infiniband Operational and Being Monitored Closely filesystem Resolved

UPDATE: Most users should no longer see any issues with Lustre.


Again, please continue to notify OSC Help of any errors you see in job output. For example, you might see "...

Read more
12 years 2 months ago 12 years 2 months ago
OpenMPI job stopped at 'There are not enough slots available in the system to satisfy the slots' Owens, Pitzer, Software Resolved

Users would encounter a MPI job failed with openmpi/3.1.0-hpcx on Owens and Pitzer. The job would stop with the error  like "There are not enough slots available in the system to...

Read more
6 years 2 months ago 6 years 1 month ago
ArcGIS License problems Software Resolved

We are experiencing problems with the ArcGIS license server. We will resume working on restoring access to this software on October 24th, 2018.

=====

It is fixed and running...

Read more
7 years 11 months ago 7 years 11 months ago
Ansys OMP: System error #22: Invalid argument Cardinal Resolved
(workaround)

You may encounter the following error while running Ansys on Cardinal:

OMP: Error #100: Fatal system error detected.
OMP: System error #22: Invalid argument
forrtl: error (76): Abort...
Read more
1 year 9 months ago 1 year 5 months ago