Cannot use mpiexec/mpirun from OpenMPI in an interactive session Owens, Pitzer, Software Resolved
(workaround)

We found mpiexec/mpirun from OpenMPI can not be used in an interactive session (launched by sinteractive) after upgrading Pitzer and... Read more

3 years 1 month ago 2 years 4 weeks ago
Rolling reboot of all clusters, starting from 8 AM Tuesday, June 19, 2018 Batch, Owens, Ruby Resolved

Posted on June 12, 2018, at 4:40 PM:

We will have rolling reboots of three clusters (Owens, Ruby, and Oakley) including login and compute nodes, starting from 8 AM Tuesday... Read more

5 years 10 months ago 5 years 10 months ago
Intermittent DNS issues Resolved

3/9/15 Update: The DNS issues have been resolved.  In total, the following services may have been affected by the DNS issues:

9 years 2 months ago 9 years 2 months ago
MyOSC unavailable on Tuesday, August 2, 2022, from 10 am to 12 pm client portal Resolved

We will be adding a charge account structure. MyOSC will be unavailable on Tuesday, August 2, 2022, from 10 am to 12 pm while the update occurs. See... Read more

1 year 9 months ago 1 year 9 months ago
pdsh -j broken on Oakley Batch, system software Resolved

pdsh -j is broken on Oakley.  It was broken by updates during the September downtime.  We are currently working on resolving the issue.

Users who require... Read more

8 years 4 months ago 5 years 11 months ago
MPI_THREAD_MULTIPLE is not supported with OpenMPI-HPCX 4.x Owens, Software Resolved
(workaround)

A threading code with MPI where MPI_Init_thread uses MPI_THREAD_MULTIPLE will fail because UCX from HPCX package is built without enabling multi-threading. UCX is the... Read more

1 year 2 months ago 12 months 2 days ago
HPC Job Activity Table: Save Report client portal Resolved

If you save a report at the HPC Job Activity Table, you must exit out of your web browser in order to have the report saved correctly and be able to switch in between the reports.

There is... Read more

4 years 9 months ago 4 years 1 month ago
Maintenance outage on the cluster export services Maintenance, OnDemand, Ruby Resolved

Update on 14 April 2020, 0903:

Work is completed.

Original message:

There will be maintenance on cluster export services on Tuesday, April... Read more

4 years 1 month ago 4 years 3 weeks ago
my.osc.edu is NOT available Account Management Resolved

my.osc.edu has not been fully restored after yesterday's downtime. You can change your password, but you will not be able to use the new password on my.osc.edu. The updated password will work to... Read more

6 years 11 months ago 6 years 11 months ago
Lustre, Infiniband Operational and Being Monitored Closely filesystem Resolved

UPDATE: Most users should no longer see any issues with Lustre.


Again, please continue to notify OSC Help of any errors you see in job output. For example, you might see "... Read more

9 years 9 months ago 9 years 8 months ago